CS5461A
5.14 Commands
All commands are 8-bits in length. Any byte that is not listed in this section is invalid. Commands that write to regis-
ters must be followed by 3 bytes of data. Commands that read data can be chained with other commands (e.g., while
reading data, a new command can be sent which can execute during the original read). All commands except reg-
ister reads, register writes, and SYNC0 & SYNC1 will abort any currently executing commands.
5.14.1 Start Conversions
B7
1
B6
1
B5
1
B4
0
B3
C3
B2
C2
B1
0
B0
0
Initiates acquiring measurements and calculating results. The device has three modes of acquisition.
C[3:2]
Modes of acquisition/measurement
00 = Perform a single computation cycle
01 = Not Used
10 = Perform continuous computation cycles
11 = Perform continuous computation cycles with APF enabled on the other channel
5.14.2 SYNC0 and SYNC1
B7
1
B6
1
B5
1
B4
1
B3
1
B2
1
B1
1
B0
SYNC
The serial port can be initialized by asserting CS or by sending three or more consecutive SYNC1 commands fol-
lowed by a SYNC0 command. The SYNC0 or SYNC1 can also be sent while sending data out.
SYNC
0 = Last byte of a serial port re-initialization sequence.
1 = Used during reads and serial port initialization.
5.14.3 Power-Up/Halt
B7
1
B6
0
B5
1
B4
0
B3
0
B2
0
B1
0
B0
0
If the device is powered-down, Power-Up/Halt will initiate a power on reset. If the part is already powered-on, all
computations will be halted.
5.14.4 Power-down and Software Reset
B7
1
B6
0
B5
0
B4
S1
B3
S0
B2
0
B1
0
B0
0
To conserve power the CS5461A has two power-down states. In stand-by state all circuitry, except the analog/digital
clock generators, is turned off. In the sleep state all circuitry, except the instruction decoder, is turned off. Bringing
the CS5461A out of sleep state requires more time than out of stand-by state, because of the extra time needed to
re-start and re-stabilize the analog oscillator.
S[1:0]
DS661F3
Power-down state
00 = Software Reset
01 = Halt and enter stand-by power saving state. This state allows quick power-on
10 = Halt and enter sleep power saving state.
11 = Reserved
23
相关PDF资料
CDB5466U BOARD EVAL & SOFTWARE CS5466 ADC
CDB5467U BOARD EVAL FOR CS5467 ADC
CDB5560-2 DEV BOARD FOR CS5560 W/SE INPUT
CDB5571-2 DEV BOARD FOR CS5571 W/SE INPUT
CDB8422 BOARD EVAL FOR CS8422 RCVR
CDB8952T BOARD EVAL FOR CS8952
CDCE906-706PERFEVM EVAL MOD PERFORMANCE CDCE906/706
CEVAL-033 BOARD EVAL FOR CVCO33 .3"X.3"
相关代理商/技术参数
CDB5461AU-Z 制造商:Cirrus Logic 功能描述:PB-FREEEVAL BOARD FOR CS5461 WITH USB - Bulk
CDB5462 制造商:Cirrus Logic 功能描述:EVAL BOARD FOR CS5462 - Bulk
CDB5463U 功能描述:数据转换 IC 开发工具 Eval Bd Sngl-Phase Pow/Energy RoHS:否 制造商:Texas Instruments 产品:Demonstration Kits 类型:ADC 工具用于评估:ADS130E08 接口类型:SPI 工作电源电压:- 6 V to + 6 V
CDB5463U-Z 功能描述:EVAL BOARD USB FOR CS5463 RoHS:是 类别:编程器,开发系统 >> 评估板 - 模数转换器 (ADC) 系列:- 产品培训模块:Obsolescence Mitigation Program 标准包装:1 系列:- ADC 的数量:1 位数:12 采样率(每秒):94.4k 数据接口:USB 输入范围:±VREF/2 在以下条件下的电源(标准):- 工作温度:-40°C ~ 85°C 已用 IC / 零件:MAX11645 已供物品:板,软件
CDB5464U 功能描述:数据转换 IC 开发工具 Eval Bd 3-Ch Sngl-Phs Pow/Energy RoHS:否 制造商:Texas Instruments 产品:Demonstration Kits 类型:ADC 工具用于评估:ADS130E08 接口类型:SPI 工作电源电压:- 6 V to + 6 V
CDB5464U-Z 制造商:Cirrus Logic 功能描述:EVAL BD PB-FREE DEMO BOARD FOR CS5464 - Boxed Product (Development Kits) 制造商:Cirrus Logic 功能描述:Eval Board
CDB5466U 功能描述:数据转换 IC 开发工具 Eval Bd F/Residental Pow-Meter Apps RoHS:否 制造商:Texas Instruments 产品:Demonstration Kits 类型:ADC 工具用于评估:ADS130E08 接口类型:SPI 工作电源电压:- 6 V to + 6 V
CDB5466U-Z 制造商:Cirrus Logic 功能描述:PB-FREEEVAL BOARD FOR CS5466 WITH USB - Bulk